Performance and Monitoring

Calculated energy consumption and
Our Passive House by the numbers.

Calculated Energy Consumption

heating energy requirements 15 kWh/m2 year (4.8 kBtu/sf/yr)
cooling energy requirement 6 kWh/m2 year (1.9 kBtu/sf/yr)
specific primary energy requirement 55 kWh/m2 year (17.5 kBtu/sf/yr)
peak heating load 12 W/m2 3.8 Btu/hr/ft2
peak cooling load 11W/m2 3.8 Btu/hr/ft2
air tightness ?? hopefully .5 ACH50
surface-to-volume ratio .67

 

Our Passive House by the Numbers

heating degree days 4838
cooling degree days 1278
finished floor area 180 sq. m, 3000 sq. ft
foundation continuous spread footing, insulated with 2" high density EPS foam
basement wall ICF with interior 2x4 wall, insulated with high density fiberglass
wall framing 12" wide double stud wall, 24" on center
wall insulation 12" blown in high density fiberglass
roof framing prefabricated trusses
roof insulation 24" blown in high density fiberglass
windows foam-filled fiberglass frames, double pane glazing with suspended film and eco-spacers, argon/krypton fill, .51 SHGC south, .31 N, E, W; average overall total unit U-value : .18 Btu/hr ft2 =1.02 W/(m2K)
ventilation system 95% sensible effectiveness ERV
heating system 98% efficient gas tankless water heater with low temperature radiant tubing in slabs
domestic hot water same
cooling system 40 SEER evaporative cooler
active system to become net zero
source energy 3.5 kW PV system
site energy 6.5 kW PV system